Jb-lighting Varyscan 4 1200 HMI Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Éclairage Jb-lighting Varyscan 4 1200 HMI. JB-Lighting Varyscan 4 1200 HMI Benutzerhandbuch Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
JB-lighting Lichtanlagentechnik GmbH
Sallersteigweg 15 D-89134 Blaustein-Wippingen
Telefon ++49(0)7304-9617-0
Telefax ++49(0)7304-9617-99
http://www.jb-lighting.de
english
Bedienungsanleitung
User Manual
Deutsch
Vue de la page 0
1 2 3 4 5 6 ... 47 48

Résumé du contenu

Page 1 - User Manual

JB-lighting Lichtanlagentechnik GmbHSallersteigweg 15 D-89134 Blaustein-WippingenTelefon ++49(0)7304-9617-0Telefax ++49(0)7304-9617-99http://www.jb-

Page 2

10 Varyscan® 4 1200 HMI 3. JB-lighting 6 Kanal Kanal 1 X-Motor Kanal 2 Y-Motor Kanal 3 Gobo Kanal 4 Farbe Kanal 5 Dimmer/Shutter Kanal 6

Page 3

11 Varyscan® 4 1200 HMI Varyscan® Nr. DMX-Adresse Schaltereinstellung 1 1 2 7 3 13 4 19 5 25 6 31 7 37 8 43 9 49 10 55

Page 4

12 Varyscan® 4 1200 HMI Varyscan® Nr. DMX-Adresse Schaltereinstellung 5 33 6 41 7 49 8 57 9 65 10 73 11 81 12 89 Best

Page 5

13 Varyscan® 4 1200 HMI Achten Sie darauf, daß das Gobo exact mit den Schlitzen in der Halterung einrastet. Wenn das Gobo richtig eingesetzt ist, l

Page 6

14 Varyscan® 4 1200 HMI Stellen Sie am DIP-Schalter Nr. 1 den Initialisierungsmodus ein (DIP-Schalterstellung siehe Seite 7) und schalten Sie Ihren

Page 7

15 Varyscan® 4 1200 HMI Effektradeinschub und den Farbradeinschub wieder ein. Vergessen Sie nicht, die Objektivhalteschraube wieder anzuziehen. 2.

Page 8

16 Varyscan® 4 1200 HMI Kanal 3 = Gobo Gobo 0 (Beam) DMX 000 - 031 Gobo 1 DMX 032 - 063 Gobo 2 DMX 064 - 095 Gobo 3 DMX 096

Page 9

17 Varyscan® 4 1200 HMI Floodfilter DMX 128 - 159 stufenlos von Flood bis offen DMX 160 - 255 2. 6 Kanäle (Clay Paky Golde

Page 10 - 4 1200 HMI

18 Varyscan® 4 1200 HMI Gobo 2 Tageslichtfilter DMX 130 - 142 Gobo 2 Prisma DMX 143 - 155 Gobo 3 weiß DMX 156 - 168 Gobo 3 Kunstlichtfil

Page 11

19 Varyscan® 4 1200 HMI Gobo 4 Prisma DMX 247 - 255 wenn am DIP-Schalter Nr. 2 Schalter 4 auf "ON" Gobo 4 Prisma DMX 247 - 254 R

Page 12

2 Varyscan® 4 1200 HMI Vorwort Sie haben sich für den Kauf des Varyscan® 4 1200 HMI von JB-lighting entschieden. Vielen Dank für das entgegengebr

Page 13

20 Varyscan® 4 1200 HMI Pin3: DMX+ rot Pin3: DMX+ rot Pin4: frei Pin4: frei Pin5: frei Pin5: frei Technische Dat

Page 14

21 Varyscan® 4 1200 HMI Stromlaufplan Varyscan* 4 1200HMI

Page 15

22 Varyscan® 4 1200 HMI Belegung der Steckerleisten und Jumper Pin Farbe Pin Farbe Pin Farbe Pin Farbe Stecker X-Motor 1 blau 2 grün 3 rot

Page 16

23 Varyscan® 4 1200 HMI R30 2R 1W R31 750R 0,6W R32 250R 0,6W R33 1,2R 1W R34 1,2R 1W R35 1,5R 1W R36 1,5R 1W R37 1,2R 1W R38 1,2R

Page 17

24 Varyscan® 4 1200 HMI Q1-Q32 BC337B P1,P2 Connector DB15 JP2 Header5 JP3,JP4,JP5 Header4 D1,D2 Bridge U1 M68HC11F1FN U2 Eprom 27C

Page 18

25 Varyscan® 4 1200 HMI Bestückungsplan Platine Varyscan® 4 1200 HMI

Page 19

26 Varyscan® 4 1200 HMI INDEX Illustration of VS 4 1200HMI...

Page 20

27 Varyscan® 4 1200 HMI Illustration of VS 4 1200HMI

Page 21

28 Varyscan® 4 1200 HMI Back view and position of operating sections Occupation of DMX-sockets DMX-in DMX-out Pin No. signal Co

Page 22

29 Varyscan® 4 1200 HMI Put in/ Exchange of the Bulb Warning: Before opening pull out mains plug! Loosen the screws at the lid of your Varyscan® w

Page 23

3 Varyscan® 4 1200 HMI Inhaltsverzeichnis Abbildung VS4 1200 HMI...

Page 24

30 Varyscan® 4 1200 HMI Test Mode To see the variety of functions of your Varyscan® easily, start the test mode by turning switch 3 off and switch 2

Page 25

31 Varyscan® 4 1200 HMI DIP-switch position: DIP-switch No.2 switch 2 off, switch 3 on 3. JB-lighting 6 channel drive mode channel 1 x-mot

Page 26

32 Varyscan® 4 1200 HMI 6 31 7 37 8 43 9 49 10 55 11 61 12 67 In 8 channel drive mode addresses have to be adjusted in 8 st

Page 27

33 Varyscan® 4 1200 HMI 11 81 12 89 Definition of DIP-switch positions for defined DMX-addresses Every single DIP-switch responds to t

Page 28

34 Varyscan® 4 1200 HMI 1. Gobos JB-size Outside diameter: 68,0 mm Use diameter: 49,0 mm 2. Standard size (M-size) Outside diameter:

Page 29

35 Varyscan® 4 1200 HMI Adjustment of the mirror stop To adjust the mirror of your Varyscan® 1200 HMI, proceed as follows: Adjust the initialisatio

Page 30

36 Varyscan® 4 1200 HMI You should clean the optical parts of your Varyscan® periodically to restore maximum brightness of the scan. After having op

Page 31

37 Varyscan® 4 1200 HMI Occupation of channels for Varyscan® 4 1200 HMI 1. JB lighting 8 channels Channel 1 X-movement Channel 2 Y-movment Ch

Page 32

38 Varyscan® 4 1200 HMI shutter open DMX 244 - 255 channel 6 = iris iris (linear) DMX 000 - 255 channel 7 = rotating gobos (positioning and

Page 33

39 Varyscan® 4 1200 HMI colour 6 DMX 048 - 055 colour 7 DMX 056 - 063 colour 8 DMX 064 - 071 colour 9 DMX 072 - 079 colour 10 DMX

Page 34

4 Varyscan® 4 1200 HMI 2. Adjustment of Varyscan®...

Page 35

40 Varyscan® 4 1200 HMI channel 3 gobo and effect wheel channel 4 colour channel 5 simmer shutter channel 6 iris and goborotation channel 1 =

Page 36

41 Varyscan® 4 1200 HMI dimmer shutter closed --> blackout (BO) DMX 0 dimmer: you can perceive some light DMX 19 dimmer DMX 20 -

Page 37

42 Varyscan® 4 1200 HMI Attention: Pay attention to the polarity of the Eprom! (The inlet of the Eprom has to point to the same direction as t

Page 38

43 Varyscan® 4 1200 HMI Plan of current circuits for Varyscan® 4 1200HMI

Page 39

44 Varyscan® 4 1200 HMI Occupation of connectors and Jumper Pin colour Pin colour Pin colour Pin colour connector x-motor 1 blue 2 green 3 r

Page 40

45 Varyscan® 4 1200 HMI R27 300R 0,6W R28 150R 0,6W R29 2R 1W R30 2R 1W R31 750R 0,6W R32 250R 0,6W R33 1,2R 1W R34 1,2R 1W R35 1,5

Page 41

46 Varyscan® 4 1200 HMI JP3,JP4,JP5 Header4

Page 42

47 Varyscan® 4 1200 HMI D1,D2 Bridge U1 M68HC11F1FN U2 Eprom 27C256 U3 AM26LS32 IC DMX-IN U4 PAL22V10 U5 74HC245 U6 no. U7 PBL3771 d

Page 43

48 Varyscan® 4 1200 HMI Plan of electronic parts for electronic board of Varyscan® 4 1200 HMI

Page 44

5 Varyscan® 4 1200 HMI Abbildung VS4 1200 HMI

Page 45

6 Varyscan® 4 1200 HMI Rückansicht und Lage der Bedienelemente Belegung der DMX-Buchsen DMX-Eingang DMX-Ausgang Pin Nr. Signal Kab

Page 46

7 Varyscan® 4 1200 HMI Auspacken der Varyscan® Anlage Vor Ihnen befindet sich die komplette Varyscan®-Anlage. Entnehmen Sie zuerst alle Teile aus

Page 47

8 Varyscan® 4 1200 HMI Inbetriebnahme der Anlage 1. Varyscan® aufhängen Um die optimale Funktionsfähigkeit der Varyscan® auszuschöpfen, sollten Si

Page 48

9 Varyscan® 4 1200 HMI Farbwechsel stufenlos: DIP-Schalter Nr.2 Schalter 1 d.h. wenn diese Funktion eingeschaltet ist, entspricht jeder DMX-Wert zw